Auxiliary Heat in Heat Pump Systems

What this covers

  • What Auxiliary Heat Is
  • Trigger One: It Is Genuinely Cold
  • Trigger Two: A Large Thermostat Setback
  • Trigger Three: The Wrong Thermostat
  • Trigger Four: Emergency Heat Left On
  • How to Tell Which One You Have
  • When It Is a Genuine Fault
  • The Takeaway

A heat pump that is running normally is one of the cheapest ways to heat a house. The same heat pump running on auxiliary heat is one of the most expensive.

The switch between those two states is made by the thermostat, not by you, and the logic it uses surprises people. Here is what actually triggers it.

What Auxiliary Heat Is

A heat pump has a backup heat source for the hours it cannot manage alone.

On an all-electric system that backup is normally electric resistance strips in the air handler. Strips are simple and reliable and they convert electricity to heat at a ratio of one to one. A heat pump in reasonable conditions delivers several units of heat per unit of electricity, which is the entire reason to own one. So strip heat costs multiples of what the heat pump costs for the same warmth.

On a dual fuel system the backup is a gas furnace, which is cheaper to run than strips but still normally more expensive per unit of heat than the heat pump in mild cold.

Either way, backup heat is the expensive mode, and the goal is for it to run when it is needed and not otherwise.

Trigger One: It Is Genuinely Cold

The legitimate case. Below a certain outdoor temperature the heat pump cannot keep up with the house’s heat loss, so the backup joins in.

This is the system working. Nothing to fix. It should correspond to genuinely cold weather, not to a mild evening.

Trigger Two: A Large Thermostat Setback

The case that catches almost everybody, because it feels like good practice.

Set the house back eight degrees overnight to save money. In the morning the thermostat compares where the house is with where it should be, sees a large gap, and decides it needs to close that gap quickly. Many thermostats respond by bringing on auxiliary heat.

So the overnight saving gets spent, often more than spent, on resistance heat during the recovery.

This produces a rule that runs against the usual advice. Large setbacks suit a furnace and work against a heat pump. A furnace recovers quickly at its normal running cost. A heat pump recovers slowly, and asking it to recover quickly means asking for the backup.

Two or three degrees is fine. Eight is self-defeating.

Trigger Three: The Wrong Thermostat

A thermostat is not a generic component on a heat pump.

A proper heat pump thermostat knows what it is driving. It ramps the recovery gradually specifically to avoid calling the strips, it understands staging, and it has a configuration for the changeover.

A generic replacement thermostat, installed by somebody who did not check what was downstream of it, does none of that. It treats a gap in temperature as something to close as fast as possible, which on a heat pump means the expensive mode.

This is a real and common cause of a bill that rose for no apparent reason after a thermostat was changed.

Trigger Four: Emergency Heat Left On

The most expensive of the four and the easiest to miss.

Emergency heat is a manual override. It runs the backup alone and locks the heat pump out completely. It exists for a broken heat pump, so the house still gets heat while a repair is arranged.

Switched on during a cold snap and never switched back, it runs the most expensive heat source continuously. The house is warm, nothing sounds wrong, and the only symptom is the bill.

If a light or a display on the thermostat indicates emergency heat and the weather is not severe, that is worth dealing with today rather than at the next service visit.

How to Tell Which One You Have

A week of casual observation settles it, no tools required.

Note when the indicator appears, and what it is outside. Most thermostats show auxiliary or emergency heat. Write down the outdoor temperature when it comes on. If it engages around 45 degrees, something is wrong. If it engages in genuinely cold weather, that is normal.

Note whether it appears during recovery. If it comes on every morning as the house warms up from a setback and not at other times, the setback is the cause.

Check whether the indicator ever goes off. If it is on permanently, suspect emergency heat or a fault.

Look at the thermostat model. If it was replaced at some point and nobody mentioned heat pumps, that is a lead.

Anyone doing west Springfield heating and cooling service on heat pumps sees this pattern often enough to recognize it from the description, and the fix is usually a setting rather than a part.

When It Is a Genuine Fault

Backup heat running when it should not can also point at something real.

A heat pump low on refrigerant delivers less heat, so the backup fills the gap. A failing reversing valve can leave the system heating weakly or not at all. A defrost control stuck in defrost keeps calling the backup to cover for it. A dirty outdoor coil reduces capacity the same way.

In each of those cases the backup is doing its job and masking a problem underneath. That is why a bill rising without any change in habits is worth a diagnosis rather than a shrug: the system is working, which is exactly what makes it easy to ignore.

Proper year round system service on a heat pump looks at both modes, because a fault can show in heating and hide in cooling.

The Takeaway

Auxiliary heat is the expensive mode and four things call it in: real cold, a large thermostat setback, a thermostat that does not know it is driving a heat pump, and emergency heat left switched on.

Watch when the indicator appears and what the outdoor temperature is. Keep setbacks small. Check that emergency heat is off. If it runs in mild weather, treat it as a diagnosis rather than a setting.